Do you need a program to calculate the lighting of hundreds of straight roads automatically following the EN 13201 standard, without wasting time?
If so, Road Plus, the extra module for road lighting of LITESTAR 4D Litecalc, is perfect for you.
This is achieved by using an Excel file structured by OxyTech for this purpose, which can also be used as a tool for city census, featuring:
- an Input section for entering the general data of the road, its geometric dimensions, the data of the luminaires through the relative photo-spectrometric files and their installation
- an Output section where the program saves the results during the calculation process
Range Function
Road Plus is equipped with the innovative Range function that can be used for many fields such as the distance between the poles, the installation height, the retraction of the pole, the inclination of the luminaire and its maintenance factor.
Multiple Photometries
It is also possible to launch the same calculation with an n number of photometries for the same project: in this case, as in the case of the ranges, the program automatically generates n lines of the Excel file, as many as the files and/or ranges.
Photometries can be IES LM-63, IESxml, Eulumdat, OXL or UNIxml types.
Optimization Function
Road Plus is equipped with an optimization function with which the program directly identifies the optimal solution in terms of LED supply current, flux and luminaire power.
The current, flux and power values determined by the program are recorded in the Output Excel file and are the optimal ones for achieving the lighting levels required by law according to the road class.
This solution avoids the large number of calculations needed when the data is provided via Eulumdat files, each characterized by a single series of flux, power (and current) values.
This is possible through the use of OXL photometric files in which the flux and power curves of the luminaire have been entered according to the LED supply current.
Results Saving
The program saves not only the results in the Output section of the Excel file but also the project file and the printouts in PDF in the Output folder selecter by the user.
Results are expressed in illuminance and luminance for all surfaces with the relative uniformities as well as the values of fTI and REI.
The results of the energy efficiency parameters (IPEA *, IPEI *, UF, power density and overall efficiency) as well as those of the luminare used (flux, power, G *, D, DFF, UL and UH) are also saved.
The Excel file also displays the comparison check of the values obtained with the EN 13201 standard table showing the solutions that pass and the ones which do not pass.
The Search for the Best Solution
The arrangement of the results in the Excel file allows to quickly search for the best solution by using the Filter function applicable to each calculated parameter.
The Excel File: Summary for the Future
The Road Plus Excel file is an indispensable tool for summarizing and archiving the results for future reference.
Watch the introduction film about Road Plus
References